Amplifier
Amplifier is not a signal conditioner.
High
A wave guide acts as a high pass filter.
Galiometer
Galiometer is used to measure frequency in waveguide.
Schering?s bridge
Wheatstone bridge
Acceleration
Flapper nozzle mechanism
Flapper nozzle mechanism is not an element of electro-pneumatic pressure transmitter.
High and negative
If calibrated on DC, they cannot be used for AC signals
Barium or strontium oxide
The cathode of a CRO is usually coated with Barium or strontium oxide.
Around one mega-ohms
The input impedance of a CRO is Around one mega-ohms.
Any of the above
A CRO can be used to measure AC Voltage, DC Voltage, frequency.
Two electron guns
A double beam oscilloscope has two electron guns.
Inside surfaces only
Phosphor coating for cathode ray tubes CRT is provided on Inside surfaces only.
The centre
The brightest spot on a cathode ray screen occurs at the centre.
Resistance temperature co-efficient
For better results a strain gauge should have low Resistance temperature co-efficient.
Measure strain in more than one direction
Rosette gauges are used to Measure strain in more than one direction.
Compensate for temperature variations
A dummy strain gauge is used to Increase the sensitivity of measuring system.
Linear displacement of core
The output of LVDT is in the form of Linear displacement of core.
Thermocouple
Thermocouple is a active transducer.