Q.

In a steam condenser, the partial pressure of steam and air are 0.06 bar and 0.007 bar respectively. The condenser pressure is

  • A0.007 bar
  • B0.053 bar
  • C0.06 bar
  • D0.067 bar
Correct Answer : (D)

0.067 bar

Hints :